Kit includes:
- no floor, ready to assemble on a concrete slab or wood foundation
- pre-cut, numbered exterior walls
- pre-cut, numbered interior walls
- pre-cut, numbered gable components
- sidewall height 95″ (2413mm)
- vaulted, cathedral ceilings
- roof pitch 2/12 (9.5 degrees)
- pre-cut 4″ x 8″ (100mm x 200mm) glulam roof purlins/beams, spaced 22″ (558mm) or less
- pre-cut, numbered 3/4″ (18mm) tongue & groove roof boards
- pre-cut, numbered fascia boards
- 9 interior doors 32″x80″ (812mm x 2040mm) or 36″ x 80″ (914mm x 2040mm), hardware
- 1 single wide wood window 21″ x 21″ (530mm x 530mm)
- 1 double wide wood window 60″ x 32″ (1530mm x 812mm) over counter top
- 8 double wide wood window 60″x39″ (1530mm x 990mm)
- 2 exterior doors 36″x80″ (990mm x 2040mm) 1/2 glass tempered, multi locking hardware
- deck posts, railing with vertical balustrades
- 2 spare wall logs/spare roof boards
- 8″ log screws to connect each row, gable components, purlins
- packaged/wrapped for sequence of assembly
- NOTE: overhead garage door not included
- FREE SHIPPING
- FOUNDATION DRAWINGS
- STAMPED STRUCTURAL ENGINEERING – manufactured to meet structural requirements for codes including California Title 24, earthquake, heavy snow load regions & hurricane zones
Exterior Stud & Siding Options:
Exterior stud & siding kits include: 2×4 or 2×6 studs, stud screws, wood siding, corner blocks
Add 14% – Otoczak Full D-Log siding 1-1/8″ x 5-1/8″ (28mm x 130mm)
Add 10% – Max Semi D-Log siding 3/4″ x 5-1/8″ (18mm x 130mm)
Window Options:
Upgrade all the wood windows to triple glazed/Low E/Argon filled glass
Add – $ 1,778.00 USD
Add – $ 2,280 CAD
OR
Upgrade all wood window to our exclusive white PVC/Shutter windows, triple glazed/Low E/ Argon filled glass plus exterior rolling shutters that are controlled from the interior. Add comfort and security, improve the energy efficiency, reduce outside noise levels & provide complete darkness for daytime sleepers. (See the video on the video section)
Add – $ 3,705.00 USD
Add – $ 4,750.00 CAD
Tip: Mineral wool insulation is recommended for log construction. It’s impervious to moisture with a higher R-value per inch than fiberglass, reduces noise levels & is environmentally friendly. Our solid wood walls add an additional R 4.4 and have virtually no heat or cold transfer, increasing the thermal & comfort benefits
Insulating the roof: Apply locally supplied materials to add rafters over the supplied tongue & groove roof boards. The build up depth is determined by the required R-value in the ceiling to meet local building codes. High density spray foam provides maximum benefits, highest R-value for thickness and water proof. These added rafters also increase the roof load capacity